X – Ray Diffraction Laser THERMO LOGG Contact Angle Analyzer Langmuir – Blodgett Film Deposition Scanning Electron Microscope with EDS (X-ray spectrometry) Small Angle X-Ray Scattering Apparatus Wide Angle X-Ray Scattering Apparatus Mercury Porosimeter Mass Spectrometer Nitrogen Porosimeter ultra-microtome AA GC-MS Scanning Electron Microscope with EDS (X-ray spectrometry) Proteome analysis [Proteomics] Remote Measurement System Transmission Electron Microscope CNC ΑGIECharmilles ΑCTSPARK FW-1P [CNC AGIE] CNC DMG CTX 510 Eco PHOTRON FASTACAM SA3 INSTRON 8801 Testing Device ROMER OMEGA R-SCAN & 3D RESHAPER LASER Cutter Pantograph with extra PLASMA torch CNC ΙDA XL 1200 Optical and Contact Coordinate Measuring Machine TESA MICRO-HITE 3D  RSV-150 Remote Sensing Vibrometer Ground Penetration Radar [GPR] Audio Magneto Telluric Optical Time Domain Reflectometers [OTDR] Non ion Rad Electric e-mat analysis Thermogravimetric Analyzers - Differential Scanning Calorimetry Magnetron Deposition Metal Deposition Grid Computing Center

HUKSEFLUX ™ THERMAL SENSORS

High accuracy thermal resistance measurement system with 2 measurement locations.
TRSYS01 is a measurement system for analysis of thermal resistance and thermal transmittance of building elements by in-situ measurement. It can be used for measurements according to ISO 9869 and ASTM C1155 / C1046 standards. In its standard configuration the system is equipped with two heat flux sensors as well as two pairs of matched thermocouples for differential temperature measurements.
      

Contact person:

Eleni Apostolidou
tel. (+30) 2510462225
This email address is being protected from spambots. You need JavaScript enabled to view it.

afm1

The in-situ measurement of thermal resistance, thermal transmittance or U-Values of buildings is often applied in studies of building elements. The thermal resistance, TR, measurement is based on simultaneous measurement of time averaged heat flux (using a heat flux sensor).

 

The ISO and ASTM standards on the subject comment on applicability of the method, on installation and on data analysis. The TRSYS consists of high accuracy electronics (measurement accuracy up to 1 microvolt) as well as matched thermocouple pairs to make a differential temperature measurement with a total accuracy of better than 0.1 degrees C. It also includes HFP01 heat flux plates. HFP01 is the world’s most popular sensor for heat flux measurement through building envelopes. 

 

TRSYS01 SPECIFICATIONS

 

Test method

 

ISO 9869 and ASTM

C1155 / C1046

Measurement locations

2 (can be increased on request)

 

Power requirements

110-220 V, 0.5 Watt (max)

 

Differential temperature (∆T)

matched pairs thermocouple type

KX, 584.3:1989

Heat flux sensor: 

 

type HFP01

 

Cable length: 

 

20 m (3x) and 10 m (3x)

 

Storage capacity

> 30 days of data:

10 minute and 24